• 7" TFT, touch screen, led backlight
• Patient managment, name and age and id.
• Multi-language options: Germany, France, Turkey, Spanish, etc
• Built-in lithium rechargeable battery, wide thermall printing system
• Memory: Store more than 1000 pieces of archive
• Auto-measurement, auto-analysis, and auto-interpretation
1. 800x480TFT Color LCD shows the working status and ECG waveform; Touch screen and soft keyboard control, more convenient for operation.
2. 12 Leads ECG simultaneous acquisition, digital signal processor, to get higher quality ECG waveforms through the AC filter, baseline filter and EMG filter of the ECG signals.
3. Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, sensitivity, speed, filter etc, to be easy for interpretation.
4. Sampling twelve leads ECG signal at the same time,analyzing 2×6+1
(rhythm lead),2×6,3×4,3×4+1(rhythm lead),4×3,4×3+1(rhythm
lead),6×2,6×2+1(rhythm lead)recording mode at the same time,and
reporting with multi-formats.
5. The power supply includes both AC/DC. This device includes built-in lithium polymer rechargeable battery. It can standby for 4 hours, print 150 pieces of ECG waveform and print 90 minutes continually under the best DC state to satisfy the need of visiting patients and physical examination.
6. It has build-in storage with large capacity, and can memory more than 1000 cases, which is easy for doctor review and statistic.
7. Under the review mode, you can see the saved ECG waveform, auto-
analysis and auto-interpretation of ECG waveform parameter, auto-
interpretation conclusion.
8. Support Chinese, English, Italian and Turkish operating interface, can print out Chinese or Endlish, Italian, Turkish report.
Input mode | floating and defibrillation protection |
Frequency response | 0.05Hz ~ 150Hz(-3dB~+0.4dB) |
CMRR | >60dB, >100dB(add filter) |
Time | constant:≥ 3.2s |
Patient leak current | <10µA |
Calibration voltage | 1mV |
Sensitivity | 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% |
Noise level | <15µVp-p |
Input circuit current | ≤50nA |
Input impedance | ≥50MΩ |
Sampling accuracy | 12-bit |
Safety classification: | class I, type CF and defibrillation-proof applied part |
Recording mode | thermal printing system |
Auto record | set record according to auto record format and mode, automatically switching leads, measuring and analyzing. |
Rhythm record | set record according to rhythm record format and mode, automatically measuring and analyzing. |
Manual record | set record according to record format, manually switching leads. |
Measurement parameters | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) |
Paper size | 80mm(W)×20m(L) |
Power frequency filter | AC 50Hz/60Hz(-20dB) |
Sampling frequency | 1000Hz |
EMG interference filter | 25Hz/35Hz (-3dB) |
Paper speed |
Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% |